Resultados 1 - 20 de 441
Filtrar
1.
IEEE Trans Med Imaging ; 42(4): 1009-1020, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36383595

RESUMO

Optical Coherence Tomography Angiography (OCTA), a functional extension of OCT, has the potential to replace most invasive fluorescein angiography (FA) exams in ophthalmology. So far, OCTA's field of view is however still lacking behind fluorescence fundus photography techniques. This is problematic, because many retinal diseases manifest at an early stage by changes of the peripheral retinal capillary network. It is therefore desirable to expand OCTA's field of view to match that of ultra-widefield fundus cameras. We present a custom developed clinical high-speed swept-source OCT (SS-OCT) system operating at an acquisition rate 8-16 times faster than today's state-of-the-art commercially available OCTA devices. Its speed allows us to capture ultra-wide fields of view of up to 90 degrees with an unprecedented sampling density and hence extraordinary resolution by merging two single shot scans with 60 degrees in diameter. To further enhance the visual appearance of the angiograms, we developed for the first time a three-dimensional deep learning based algorithm for denoising volumetric OCTA data sets. We showcase its imaging performance and clinical usability by presenting images of patients suffering from diabetic retinopathy.


Assuntos
Angiografia , Oftalmologia , Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Retinopatia Diabética/diagnóstico por imagem , Angiofluoresceinografia/normas , Doenças Retinianas/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Angiografia/instrumentação , Angiografia/métodos , Angiografia/normas , Oftalmologia/instrumentação , Oftalmologia/métodos
2.
Sci Data ; 9(1): 580, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36138025

RESUMO

In the application of deep learning on optical coherence tomography (OCT) data, it is common to train classification networks using 2D images originating from volumetric data. Given the micrometer resolution of OCT systems, consecutive images are often very similar in both visible structures and noise. Thus, an inappropriate data split can result in overlap between the training and testing sets, with a large portion of the literature overlooking this aspect. In this study, the effect of improper dataset splitting on model evaluation is demonstrated for three classification tasks using three OCT open-access datasets extensively used, Kermany's and Srinivasan's ophthalmology datasets, and AIIMS breast tissue dataset. Results show that the classification performance is inflated by 0.07 up to 0.43 in terms of Matthews Correlation Coefficient (accuracy: 5% to 30%) for models tested on datasets with improper splitting, highlighting the considerable effect of dataset handling on model evaluation. This study intends to raise awareness on the importance of dataset splitting given the increased research interest in implementing deep learning on OCT data.


Assuntos
Aprendizado Profundo , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
3.
Sci Rep ; 12(1): 1412, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082355

RESUMO

Retinal segmentation is a prerequisite for quantifying retinal structural features and diagnosing related ophthalmic diseases. Canny operator is recognized as the best boundary detection operator so far, and is often used to obtain the initial boundary of the retina in retinal segmentation. However, the traditional Canny operator is susceptible to vascular shadows, vitreous artifacts, or noise interference in retinal segmentation, causing serious misdetection or missed detection. This paper proposed an improved Canny operator for automatic segmentation of retinal boundaries. The improved algorithm solves the problems of the traditional Canny operator by adding a multi-point boundary search step on the basis of the original method, and adjusts the convolution kernel. The algorithm was used to segment the retinal images of healthy subjects and age-related macular degeneration (AMD) patients; eleven retinal boundaries were identified and compared with the results of manual segmentation by the ophthalmologists. The average difference between the automatic and manual methods is: 2-6 microns (1-2 pixels) for healthy subjects and 3-10 microns (1-3 pixels) for AMD patients. Qualitative method is also used to verify the accuracy and stability of the algorithm. The percentage of "perfect segmentation" and "good segmentation" is 98% in healthy subjects and 94% in AMD patients. This algorithm can be used alone or in combination with other methods as an initial boundary detection algorithm. It is easy to understand and improve, and may become a useful tool for analyzing and diagnosing eye diseases.


Assuntos
Algoritmos , Degeneração Macular/diagnóstico por imagem , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Artefatos , Feminino , Humanos , Degeneração Macular/patologia , Pessoa de Meia-Idade , Retina/anatomia & histologia , Retina/patologia
4.
Coron Artery Dis ; 33(2): 114-124, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34411011

RESUMO

OBJECTIVES: We investigated clinical determinants of disease burden and vulnerability using optical coherence tomography (OCT) co-registered with intravascular ultrasound (IVUS) in a large cohort of patients. METHODS: A total of 704 patients [44.5% with acute coronary syndromes (ACS)] underwent coronary intervention. IVUS plaque burden and OCT lipid, macrophage and calcium indices and the presence of thrombus, plaque rupture and thin-cap fibroatheroma (TCFA) were analyzed. RESULTS: Median patient age was 66 years with 81.8% men, 34.4% with diabetes mellitus and 15.5% with preadmission statins. Median lesion length was 25.7 mm, and 33.0% had a TCFA. Adjusted models indicated (1) older patient age was related to more calcium, but fewer macrophages; (2) men were related to more thrombus with plaque rupture while women had more thrombus without plaque rupture; (3) ACS presentation was related to morphological acute thrombotic events (more thrombus with/without rupture) and plaque vulnerability (more TCFA, more lipid and macrophages and larger plaque burden); (4) diabetes mellitus was related to a greater atherosclerotic disease burden (more lipid and calcium and larger plaque burden) and more thrombus without rupture; (5) hypertension was related to more macrophages; (6) current smoking was related to less calcium; and (7) renal insufficiency and preadmission statin therapy were not independently associated with IVUS or OCT plaque morphology. CONCLUSION: Patient characteristics, especially diabetes mellitus and aging, affect underlying atherosclerotic burden, among which a greater lipidic burden along with sex differences influence local thrombotic morphology that affects clinical presentation.


Assuntos
Doença da Artéria Coronariana/etiologia , Tomografia de Coerência Óptica/normas , Ultrassonografia de Intervenção/normas , Idoso , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Efeitos Psicossociais da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
5.
Acta Ophthalmol ; 100(2): e368-e376, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34309204

RESUMO

This work is a systematic review and meta-analysis to evaluate the diagnostic accuracy of optical coherence tomography angiography (OCTA) in the identification of choroidal neovascularization due to age-related macular degeneration (AMD) in comparison with fluorescein angiography (FA). A systematic search of the literature was carried out on Medline, EMBASE, Web of Science, Cochrane Library and Center for Reviews and Dissemination. Studies comparing OCTA with FA for the diagnosis of choroidal neovascularization due to AMD that included data on the diagnostic validity of the test or the data necessary for its calculation were selected. The QUADAS-2 tool was used to assess the risk of bias in selected studies. The quantitative analysis of the results was performed by meta-analysis. Seven primary studies were included. The quality of the evidence was good. The total population included in the meta-analysis comprised 553 eyes, with a cumulative sensitivity and specificity of 85.9% (95% CI 81.9-89.3%) and 89% (95% CI 83.5-93.2%), respectively, cumulative positive and negative likelihood ratios of 8.36 and 0.15, respectively (95% CI of 3.05-22.890 and 0.09-0.24, respectively), and a cumulative diagnostic odds ratio of 67.21 (95% CI 22.58-200.05). The evidence obtained does not demonstrate the superiority of OCTA over FA. Its use as a support technique could improve patient flow and reduce the number of FA.


Assuntos
Neovascularização de Coroide/diagnóstico por imagem , Degeneração Macular/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Angiofluoresceinografia/normas , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
6.
Acta Ophthalmol ; 100(2): e377-e385, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34363322

RESUMO

Biomarkers of ocular blood flow originating from a wide variety of imaging modalities have been associated with glaucoma onset and progression for many decades. Advancements in imaging platforms including optical coherence tomography angiography (OCTA) have provided the ability to quantify vascular changes in glaucoma patients, alongside traditional measures such as retinal nerve fibre layer thickness and optic nerve head structure. Current literature on vascular biomarkers, as measured by OCTA, indicates significant relationships between glaucoma and blood flow and capillary density in the retina and ONH. The data currently available, however, are highly diverse and lack robust longitudinal data on OCTA vascular outcomes and glaucoma progression. Herein we discuss and summarize the relevant current literature on OCTA vascular biomarkers and glaucoma reviewed through March 1, 2021. Associations between OCTA vascular biomarkers and clinical structural and functional glaucoma outcomes as well as differences between glaucoma patients and healthy controls are reviewed and summarized. The available data identify significantly decreased flow density, flow index and vessel density in the ONH, peripapillary vascular layer and macula of glaucoma patients compared with controls. Whole image vessel density is also significantly decreased in glaucoma patients compared with controls, and this outcome has been found to correspond to severity of visual field loss. OCTA vascular biomarkers alongside clinical structural outcomes may aid in assessing overall risk for glaucoma in patients.


Assuntos
Glaucoma/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Biomarcadores/análise , Angiofluoresceinografia/efeitos adversos , Humanos , Macula Lutea/irrigação sanguínea , Disco Óptico/irrigação sanguínea , Tomografia de Coerência Óptica/normas
7.
Sci Rep ; 11(1): 23832, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34903817

RESUMO

This is a prospective observational study to establish the short- and long-term repeatability of measurements of peripapillary optical coherence tomography angiography (OCTA) parameters in healthy eyes and identify factors affecting long-term repeatability. We enrolled 84 healthy eyes. Participants with a history of any ophthalmic disease (except high myopia) or intraocular surgery were excluded from the study. An experienced examiner performed OCTA using disc-centered 6 × 6 mm scans. All examinations were conducted twice at 5-min intervals at the initial visit and repeated at least 6 months later. For short-term repeatability, the coefficient of variation (CV) was 2.94-4.22% and the intraclass correlation coefficient (ICC) was 0.840-0.934. For long-term repeatability, the CV was 2.73-3.84% and the ICC was 0.737-0.934. Multivariate analyses showed that the axial length (AL) (B = 0.970; p = 0.002) and mean signal strength (SS) (B = - 2.028; p < 0.001) significantly affected long-term repeatability. Measurements of peripapillary OCTA parameters exhibited excellent short-term and good long-term repeatability in healthy individuals. The mean SS and AL affected long-term repeatability and should be considered while interpreting peripapillary OCTA images.


Assuntos
Angiografia/métodos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Angiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas
8.
Sci Rep ; 11(1): 23886, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34903831

RESUMO

Glaucoma is an optic neuropathy that results in the progressive loss of retinal ganglion cells (RGCs), which are known to exhibit functional changes prior to cell loss. The electroretinogram (ERG) is a method that enables an objective assessment of retinal function, and the photopic negative response (PhNR) has conventionally been used to provide a measure of RGC function. This study sought to examine if additional parameters from the ERG (amplitudes of the a-, b-, i-wave, as well the trough between the b- and i-wave), a multivariate adaptive regression splines (MARS; a non-linear) model and achromatic stimuli could better predict glaucoma severity in 103 eyes of 55 individuals with glaucoma. Glaucoma severity was determined using standard automated perimetry and optical coherence tomography imaging. ERGs targeting the PhNR were recorded with a chromatic (red-on-blue) and achromatic (white-on-white) stimulus with the same luminance. Linear and MARS models were fitted to predict glaucoma severity using the PhNR only or all ERG markers, derived from chromatic and achromatic stimuli. Use of all ERG markers predicted glaucoma severity significantly better than the PhNR alone (P ≤ 0.02), and the MARS performed better than linear models when using all markers (P = 0.01), but there was no significant difference between the achromatic and chromatic stimulus models. This study shows that there is more information present in the photopic ERG beyond the conventional PhNR measure in characterizing RGC function.


Assuntos
Eletrorretinografia/normas , Glaucoma de Ângulo Aberto/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Eletrorretinografia/métodos , Feminino , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Masculino , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/normas
9.
Front Endocrinol (Lausanne) ; 12: 777552, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34956088

RESUMO

Diabetic retinopathy, the most serious ocular complication of diabetes, imposes a serious economic burden on society. Automatic and objective assessment of vessel changes can effectively manage diabetic retinopathy and prevent blindness. Optical coherence tomography angiography (OCTA) metrics have been confirmed to be used to assess vessel changes. The accuracy and reliability of OCTA metrics are restricted by vessel segmentation methods. In this study, a multi-branch retinal vessel segmentation method is proposed, which is comparable to the segmentation results obtained from the manual segmentation, effectively extracting vessels in low contrast areas and improving the integrity of the extracted vessels. OCTA metrics based on the proposed segmentation method were validated to be reliable for further analysis of the relationship between OCTA metrics and diabetes and the severity of diabetic retinopathy. Changes in vessel morphology are influenced by systemic risk factors. However, there is a lack of analysis of the relationship between OCTA metrics and systemic risk factors. We conducted a cross-sectional study that included 362 eyes of 221 diabetic patients and 1,151 eyes of 587 healthy people. Eight systemic risk factors were confirmed to be closely related to diabetes. After controlling these systemic risk factors, significant OCTA metrics (such as vessel complexity index, vessel diameter index, and mean thickness of retinal nerve fiber layer centered in the macular) were found to be related to diabetic retinopathy and severe diabetic retinopathy. This study provides evidence to support the potential value of OCTA metrics as biomarkers of diabetic retinopathy.


Assuntos
Retinopatia Diabética/diagnóstico , Vasos Retinianos/patologia , Tomografia de Coerência Óptica , Idoso , Angiografia/métodos , Angiografia/normas , Contagem de Células/normas , China , Estudos Transversais , Retinopatia Diabética/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Valores de Referência , Retina/diagnóstico por imagem , Retina/patologia , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
10.
Ann Clin Transl Neurol ; 8(12): 2235-2251, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34792863

RESUMO

OBJECTIVE: To evaluate changes over 3 years in the thickness of inner retinal layers including the peripapillary retinal nerve fiber layer (pRNFL), and combined macular ganglion cell and inner plexiform layers (mGCIPL), in individuals with relapsing-remitting multiple sclerosis (RRMS) versus healthy controls; to determine whether optical coherence tomography (OCT) is sufficiently sensitive and reproducible to detect small degrees of neuroaxonal loss over time that correlate with changes in brain volume and disability progression as measured by the Expanded Disability Status Scale (EDSS). METHODS: Individuals with RRMS from 28 centers (n = 333) were matched with 64 healthy participants. OCT scans were performed on Heidelberg Spectralis machines (at baseline; 1 month; 6 months; 6-monthly thereafter). RESULTS: OCT measurements were highly reproducible between baseline and 1 month (intraclass correlation coefficient >0.98). Significant inner retinal layer thinning was observed in individuals with multiple sclerosis (MS) compared with controls regardless of previous MS-associated optic neuritis--group differences (95% CI) over 3 years: pRNFL: -1.86 (-2.54, -1.17) µm; mGCIPL: -2.03 (-2.78, -1.28) µm (both p < 0.0001; effect sizes 0.39 and 0.34). Greater inner retinal layer atrophy was observed in individuals diagnosed with RRMS <3 years versus >5 years (pRNFL: p < 0.05; mGCIPL: p < 0.01). Brain volume decreased by 1.3% in individuals with MS over 3 years compared to 0.5% in control subjects (effect size 0.76). mGCIPL atrophy correlated with brain atrophy (p < 0.0001). There was no correlation of OCT data with disability progression. INTERPRETATION: OCT has potential to estimate rates of neurodegeneration in the retina and brain. The effect size for OCT, smaller than for magnetic resonance imaging based on Heidelberg Spectralis data acquired in this study, was increased in early disease.


Assuntos
Encéfalo/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Adulto , Atrofia/diagnóstico por imagem , Atrofia/patologia , Encéfalo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla Recidivante-Remitente/patologia , Estudos Prospectivos , Retina/patologia
11.
Sci Rep ; 11(1): 19754, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34611277

RESUMO

Posterior vitreous detachment (PVD) is a separation between the posterior vitreous cortex and internal limiting membrane. Although PVD was historically considered an acute event, recent studies using spectral-domain optical coherence tomography (SD-OCT) revealed a gradual progression of PVD in healthy subjects. Although SD-OCT improved PVD studies, the narrow imaging angle and long examination time were problematic to allow wide angle capture. The Xephilio OCT-S1 (Canon), a swept-source OCT (SS-OCT) device, can obtain up to 23-mm of widefield B-scan images in a single acquisition. We used this widefield SS-OCT to quantitatively evaluate the PVD stage in 214 healthy subjects aged 4-89 years and determine whether PVD stages differ between the bilateral eyes of each patient. Age was significantly positively correlated with the overall PVD stage (ρ = 0.7520, P < 0.001). Interestingly, partial PVD occurred in children as young as 5 years, indicating that initial PVD onset may occur much earlier than previously reported. Furthermore, PVD stages of the bilateral eyes were highly consistent in 183 subjects (85.5%). Widefield 23-mm SS-OCT thus revealed that PVD started earlier than anticipated, and age was correlated with the symmetry of PVD stage. Widefield 23-mm SS-OCT may also be clinically useful for the evaluation of diseased eyes.


Assuntos
Tomografia de Coerência Óptica/métodos , Descolamento do Vítreo/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Índice de Gravidade de Doença , Tomografia de Coerência Óptica/normas , Corpo Vítreo , Adulto Jovem
12.
Sci Rep ; 11(1): 19498, 2021 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-34593894

RESUMO

Optical coherence tomography (OCT) images is widely used in ophthalmic examination, but their qualities are often affected by noises. Shearlet transform has shown its effectiveness in removing image noises because of its edge-preserving property and directional sensitivity. In the paper, we propose an adaptive denoising algorithm for OCT images. The OCT noise is closer to the Poisson distribution than the Gaussian distribution, and shearlet transform assumes additive white Gaussian noise. We hence propose a square-root transform to redistribute the OCT noise. Different manufacturers and differences between imaging objects may influence the observed noise characteristics, which make predefined thresholding scheme ineffective. We propose an adaptive 3D shearlet image filter with noise-redistribution (adaptive-SIN) scheme for OCT images. The proposed adaptive-SIN is evaluated on three benchmark datasets using quantitative evaluation metrics and subjective visual inspection. Compared with other algorithms, the proposed algorithm better removes noise in OCT images and better preserves image details, significantly outperforming in terms of both quantitative evaluation and visual inspection. The proposed algorithm effectively transforms the Poisson noise to Gaussian noise so that the subsequent shearlet transform could optimally remove the noise. The proposed adaptive thresholding scheme optimally adapts to various noise conditions and hence better remove the noise. The comparison experimental results on three benchmark datasets against 8 compared algorithms demonstrate the effectiveness of the proposed approach in removing OCT noise.


Assuntos
Modelos Teóricos , Retina/diagnóstico por imagem , Razão Sinal-Ruído , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Tomografia de Coerência Óptica/instrumentação
13.
Sci Rep ; 11(1): 19886, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34615979

RESUMO

This study aims to quantitatively investigate the optical coherence tomographic angiography (OCTA) findings of capillary congestion and its association with macular edema (ME) recurrence in chronic branch retinal vein occlusion (BRVO). We retrospectively reviewed the medical records of 115 consecutive patients with major ischemic BRVO who reached stable macula (without ME for two consecutive visits) at baseline (the first visit within the stable period). All patients were classified into a recurrence or non-recurrence groups depending on ME recurrence. Capillary congestion of deep capillary plexuses (DCP-C) and other abnormal capillary lesions were segmented, and their areas, vascular densities, and mean retinal thicknesses (MRT) were calculated. The main outcomes were differences between the two groups and risk factors for recurrence among baseline and OCTA parameters. A total of 76 eyes were included, of which 22 (28.9%) recurred. DCP-C existed in all eyes at baseline. MRT of DCP-C (p = 0.006) was greater in the recurrence group. Greater MRT of DCP-C (OR: 1.044; p = 0.002) and more frequent intravitreal injections (OR: 1.803; p < 0.001) were associated with a higher risk of relapsing ME. DCP-C may contribute to the anatomical stability of chronic BRVO and simultaneously be the source of ME.


Assuntos
Edema Macular/diagnóstico , Edema Macular/etiologia , Oclusão da Veia Retiniana/diagnóstico por imagem , Oclusão da Veia Retiniana/patologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Biomarcadores , Doença Crônica , Comorbidade , Suscetibilidade a Doenças , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Oclusão da Veia Retiniana/complicações , Estudos Retrospectivos , Fatores de Risco , Tomografia de Coerência Óptica/normas
14.
Sci Rep ; 11(1): 18068, 2021 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34508170

RESUMO

To investigate choroidal neovascularization (CNV) characteristics after anti-vascular endothelial growth factor (anti-VEGF) therapy in patients with neovascular age-related macular degeneration by optical coherence tomography angiography (OCTA) and to assess the potential predictive role of combined qualitative and quantitative biomarkers for disease activity. Patients diagnosed with type 1 or type 2 CNV via multimodal imaging who had received anti-VEGF treatment were retrospectively reviewed. Qualitative and quantitative CNV responses on OCTA after serial injections were analyzed. The enrolled eyes were divided into two groups based on treatment intervals during follow-up, including an active group with less than 12 weeks intervals and a stable group with 12 weeks or longer intervals. Fifty-six eyes of 56 patients were included in the study. Twenty-seven eyes (48.2%) were classified as the "active group", and 29 eyes (51.8%) were categorized as the "silent group". Qualitative biomarkers of CNV showed significant differences between the two groups (branching capillaries: 48.1% vs 6.9%, p = 0.001; anastomoses and loops: 81.5% vs 13.8%, p < 0.001; peripheral arcade: 40.7% vs 10.3%, p = 0.013, and hypointense halo: 81.5% vs 41.4%, p = 0.002). A significantly higher vessel density was found in the active group (median 39.6% vs 30.5%, p = 0.003). "Anastomoses and loops" and "vessel density" predicted an active CNV status with a probability of 93.7% and achieved the best performance. The combination of two potential biomarkers of CNV on OCTA shows good discrimination for the prediction of recurrent exudation auxiliary to structural OCT that might associate with disease activity.


Assuntos
Biomarcadores , Degeneração Macular/diagnóstico por imagem , Degeneração Macular/patologia , Tomografia de Coerência Óptica , Idoso , Neovascularização de Coroide/diagnóstico por imagem , Neovascularização de Coroide/patologia , Feminino , Angiofluoresceinografia , Humanos , Processamento de Imagem Assistida por Computador , Degeneração Macular/etiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Acuidade Visual
15.
Am J Respir Crit Care Med ; 204(10): 1164-1179, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34375171

RESUMO

Rationale: Early, accurate diagnosis of interstitial lung disease (ILD) informs prognosis and therapy, especially in idiopathic pulmonary fibrosis (IPF). Current diagnostic methods are imperfect. High-resolution computed tomography has limited resolution, and surgical lung biopsy (SLB) carries risks of morbidity and mortality. Endobronchial optical coherence tomography (EB-OCT) is a low-risk, bronchoscope-compatible modality that images large lung volumes in vivo with microscopic resolution, including subpleural lung, and has the potential to improve the diagnostic accuracy of bronchoscopy for ILD diagnosis. Objectives: We performed a prospective diagnostic accuracy study of EB-OCT in patients with ILD with a low-confidence diagnosis undergoing SLB. The primary endpoints were EB-OCT sensitivity/specificity for diagnosis of the histopathologic pattern of usual interstitial pneumonia (UIP) and clinical IPF. The secondary endpoint was agreement between EB-OCT and SLB for diagnosis of the ILD fibrosis pattern. Methods: EB-OCT was performed immediately before SLB. The resulting EB-OCT images and histopathology were interpreted by blinded, independent pathologists. Clinical diagnosis was obtained from the treating pulmonologists after SLB, blinded to EB-OCT. Measurements and Main Results: We enrolled 31 patients, and 4 were excluded because of inconclusive histopathology or lack of EB-OCT data. Twenty-seven patients were included in the analysis (16 men, average age: 65.0 yr): 12 were diagnosed with UIP and 15 with non-UIP ILD. Average FVC and DlCO were 75.3% (SD, 18.5) and 53.5% (SD, 16.4), respectively. Sensitivity and specificity of EB-OCT was 100% (95% confidence interval, 75.8-100.0%) and 100% (79.6-100%), respectively, for both histopathologic UIP and clinical diagnosis of IPF. There was high agreement between EB-OCT and histopathology for diagnosis of ILD fibrosis pattern (weighted κ: 0.87 [0.72-1.0]). Conclusions: EB-OCT is a safe, accurate method for microscopic ILD diagnosis, as a complement to high-resolution computed tomography and an alternative to SLB.


Assuntos
Broncoscopia/métodos , Broncoscopia/normas , Confiabilidade dos Dados , Fibrose Pulmonar Idiopática/diagnóstico , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
PLoS One ; 16(7): e0254832, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34270605

RESUMO

PURPOSE: To assess the agreement and repeatability of horizontal visible iris diameter (HVID) or white-to-white (WTW) measurements between four imaging modalities; combination slit scanning elevation/Placido tomography, infrared biometry, dual rotating scheimpflug camera/Placido tomography, and swept source anterior segment optical coherence tomography (AS-OCT). METHODS: A prospective study of 35 right eyes of healthy volunteers were evaluated using the Orbscan IIz, IOL Master 700, Galilei G2, and DRI Triton OCT devices. The inter-device agreement and repeatability of HVID/WTW measurements for each device were analysed. RESULTS: Mean HVID/WTW values obtained by the Orbscan IIz, IOL Master 700, Galilei G2 and DRI Triton OCT were 11.77 ± 0.40 mm, 12.40 ± 0.43 mm, 12.25 ± 0.42 mm, and 12.42 ± 0.47 mm, respectively. All pairwise comparisons revealed statistically significant differences in mean HVID/WTW measurements (p = <0.01) except for the IOL Master 700-DRI OCT Triton pair (p = 0.56). Mean differences showed that the DRI Triton OCT produced the highest HVID/WTW values, followed by the IOL Master 700, Galilei G2 and Orbscan IIz, respectively. The limits of agreement were large on all device pairs. There was high repeatability for all devices (ICC ≥ 0.980). The highest repeatability was seen in the Galilei G2 (ICC = 0.995) and lowest in the Orbscan IIz (ICC = 0.980). CONCLUSIONS: The four devices exhibit high repeatability, but should not be used interchangeably for HVID/WTW measurements in clinical practice.


Assuntos
Identificação Biométrica/métodos , Iris/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Identificação Biométrica/instrumentação , Identificação Biométrica/normas , Feminino , Humanos , Raios Infravermelhos , Masculino , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/normas
17.
PLoS One ; 16(7): e0253720, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34197499

RESUMO

PURPOSE: To develop the first normative database of macular and circumpapillary scans with reference values at the level of the A-scan using the Heidelberg Spectralis Optical Coherence Tomography (OCT) machine. METHODS: This study is a retrospective cross sectional analysis of macular and circumpapillary OCT scans of healthy individuals. All participants had a full ophthalmic examination, including best corrected visual acuity, intraocular pressure, biomicroscopy, posterior segment examination and OCT scan. The volume and thickness of each of the nine Early Treatment Diabetic Retinopathy zones at the macula were analysed for the total retinal thickness, retinal nerve fibre layer (RNFL), ganglion cell layer (GCL) and inner plexiform layer (IPL). The thickness of the circumpapillary RNFL was analysed at the disc. Associations between age, gender, refractive error and OCT measurements were explored. De-identified A-scans were extracted from the OCT machine as separate tab-separated text file and made available according to the data sharing statement. RESULTS: Two-hundred eyes from 146 participants were included of which 69 (47%) were female. The mean age (SD) was 48.52 (17.52). Participants were evenly distributed across four age groups and represented nine broad ethnic groups in proportions comparable to the local distribution. All the macular scans were 20° x 20° (5.9 mm x 5.9 mm), with a total scan density between 12,800 and 49,152 A-scans. The peripapillary scans were all 12° (3.5 mm), at a scan density of 768 A-scans. The mean retinal, GCL and IPL volumes were significantly greater in males than females. Mean peripapillary RNFL thickness did not differ significantly between males and females. Age and total retinal volume (r = -0.2561, P = 0.0003), GCL volume (-0.2911, P < 0.0001) and IPL volume (-0.3194, P < 0.0001) were negatively correlated. The IPL had the strongest three significant negatively associated segments; superior inner IPL (r = -0.3444, P < 0.0001), nasal outer IPL (r = -0.3217, P < 0.0001) and inferior inner IPL (r = -0.3179, P < 0.0001). The temporal inner macular RNFL showed a statistically significant positive correlation (r = 0.1929, P = 0.0062) with age. The only significant association between age and thickness at the peripapillary disc scan was the superior temporal sector (r = -0.1910, P = 0.0067). All retinal layers were negatively correlated for refractive error, except for the central RNFL which was positively correlated (r = 0.1426, P = 0.044). CONCLUSION: This study provides a normative database of macular and circumpapillary scans with reference values at the level of the A-scan using the Heidelberg Spectralis Optical Coherence Tomography (OCT) machine.


Assuntos
Glaucoma/diagnóstico , Macula Lutea/diagnóstico por imagem , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico , Tomografia de Coerência Óptica/normas , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos , Tomografia de Coerência Óptica/instrumentação
18.
PLoS One ; 16(5): e0248659, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34019547

RESUMO

PURPOSE: To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. METHODS: Prospective case series at a university hospital tertiary center. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and thinnest corneal thickness (TCT) were measured using both devices in patients with keratoconus. Three groups were analyzed: eyes with no prior crosslinking or contact lens wear (Group A), eyes with prior crosslinking (Group B), and eyes with prior contact lens wear (Group C). Repeatability and agreement of measurements were analyzed. RESULTS: The study comprised of 214 eyes of 157 subjects. In Group A (n = 95 eyes), Group B (n = 86 eyes), and Group C (n = 33 eyes), intraclass correlation coefficient (ICC) was higher than 0.90 for all examined parameters, except for ACD readings in Group A with the REVO-NX (ICC = 0.83). Differences in ACD, TCT, and CCT were significantly different between the two devices for Groups A, B and C (p<0.05). AL measurements differed significantly in Groups A and B (p<0.05) but not in Group C (p = 0.18). Repeatability did not vary significantly between Groups A, B, or C in any parameter with both devices (p>0.05). There was poor agreement between the two devices across all parameters (p<0.05). CONCLUSIONS: Both devices demonstrated good repeatability but poor agreement across AL, ACD, CCT and TCT measurements. There was no significant difference in repeatability in virgin eyes compared to eyes with prior crosslinking or contact lens wear, however, the interchangeable use of the two devices is not recommended.


Assuntos
Identificação Biométrica/normas , Ceratocone/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Adolescente , Adulto , Identificação Biométrica/instrumentação , Identificação Biométrica/métodos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos
19.
Exp Dermatol ; 30(7): 911-922, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33884663

RESUMO

Non-invasive reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) have been extended to the dermo-cosmetic field, for skin pathophysiology understanding and therapeutics monitoring. However, standardized methodology and parameters to interpret structures and changes in these settings are still lacking. Present study aimed to propose a validated standard methodology and a list of defined parameters for objective non-pathological skin assessments in the cosmetically sensitive cheekbone area of the face. OCT and RCM quantitative, semi-quantitative and qualitative features were considered for assessments. Validation process included 50 sets of images divided into two age groups. Inter-rater reliability was explored to assess the influence of the proposed methodology. Quantitative OCT parameters of "epidermal thickness," "density and attenuation coefficients" and "vascular density" were considered and calculated. Severity scales were developed for semi-quantitative OCT features of "disruption of collagen" and "vascular asset," while extent scales were produced for semi-quantitative RCM "irregular honeycomb," "mottled pigmentation" and "polycyclic papillary contours." Qualitative assessment was obtained for RCM type of collagen, and comparison between age groups was performed for all features considered. Severity visual scales assistance proved excellent inter-rater agreement across all semi-quantitative and qualitative domains. The assistance of shareable software systems allows for objective OCT quantitative parameters measurement. The use of standard reference scales, within a defined assessment methodology, offers high inter-rater reliability and thus reproducibility for semi-quantitative and qualitative OCT and RCM parameters. Taken together, our results may represent a starting point for a standardized application of RCM and OCT in dermo-cosmetic research and practice.


Assuntos
Cosméticos , Microscopia Confocal/normas , Dermatopatias/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Humanos
20.
PLoS One ; 16(2): e0246469, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33571215

RESUMO

PURPOSE: OCT-angiography (OCT-A) offers a non-invasive method to visualize retinochoroidal microvasculature. As glaucoma disease affects retinal ganglion cells in the macula, macular microcirculation is of interest. The purpose of the study was to investigate regional macular vascular characteristics in patients with ocular hypertension (OHT), pre-perimetric primary open-angle glaucoma (pre-POAG) and controls by OCT-A in three microvascular layers. MATERIAL AND METHODS: 180 subjects were recruited from the Erlangen Glaucoma Registry, the Department of Ophthalmology, University of Erlangen and residents: 38 OHT, 20 pre-POAG, 122 controls. All subjects received an ophthalmological examination including measurements of retinal nerve fibre layer (RNFL), retinal ganglion cell layer (RGC), inner nuclear layer (INL), and Bruch's Membrane Opening-Minimum Rim Width (BMO-MRW). Macular vascular characteristics (vessel density, VD, foveal avascular zone, FAZ) were measured by OCT-A (Spectralis OCT II) in superficial vascular plexus (SVP), intermediate capillary plexus (ICP), and deep capillary plexus (DCP). RESULTS: With age correction of VD data, type 3 tests on fixed effects showed a significant interaction between diagnosis and sectorial VD in SVP (p = 0.0004), ICP (p = 0.0073), and DCP (p = 0.0003). Moreover, a significance in sectorial VD was observed within each layer (p<0.0001) and for the covariate age (p<0.0001). FAZ differed significantly between patients' groups only in ICP (p = 0.03), not in SVP and DCP. For VD the AUC values of SVP, ICP, and DCP were highest among diagnostic modalities (AUC: 0.88, 95%-CI: 0.75-1.0, p<0.001). CONCLUSION: Regional reduced macula VD was observed in all three retinal vascular layers of eyes with OHT and pre-POAG compared to controls, indicating localized microvascular changes as early marker in glaucoma pathogenesis.


Assuntos
Angiografia/métodos , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Macula Lutea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/normas , Feminino , Humanos , Macula Lutea/irrigação sanguínea , Macula Lutea/inervação , Masculino , Pessoa de Meia-Idade , Nervo Óptico/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...